Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
JMIR Form Res ; 6(12): e37587, 2022 Dec 30.
Article in English | MEDLINE | ID: covidwho-2198061

ABSTRACT

BACKGROUND: Although several COVID-19 outbreaks have occurred in older adult care facilities throughout Japan, no field studies focusing on airborne infections within these settings have been reported. Countermeasures against airborne infection not only consider the air change rate (ACR) in a room but also the airflow in and between rooms. However, a specific method has not yet been established by Japanese public health centers or infectious disease-related organizations. OBJECTIVE: In April 2021, 59 COVID-19 cases were reported in an older adult care facility in Miyagi, Japan, and airborne transmission was suspected. The objective of this study was to simultaneously reproduce the ACR and aerosol advection in this facility using the carbon dioxide (CO2) tracer gas method to elucidate the specific location and cause of the outbreak. These findings will guide our recommendations to the facility to prevent recurrence. METHODS: In August 2021, CO2 sensors were placed in 5 rooms where airborne infection was suspected, and the CO2 concentration was intentionally increased using dry ice, which was subsequently removed. The ACR was then estimated by applying the Seidel equation to the time-series changes in the CO2 concentration due to ventilation. By installing multiple sensors outside the room, advection outside the room was monitored simultaneously. Aerosol advection was verified using computer simulations. Although the windows were closed at the time of the outbreak, we conducted experiments under open-window conditions to quantify the effects of window opening. RESULTS: The ACR values at the time of the outbreak were estimated to be 2.0 to 6.8 h-1 in the rooms of the facility. A low-cost intervention of opening windows improved the ventilation frequency by a factor of 2.2 to 5.7. Ventilation depended significantly on the window-opening conditions (P values ranging from .001 to .03 for all rooms). Aerosol advection was detected from the private room to the day room in agreement with the simulation results. Considering that the individual who initiated the infection was in the private room on the day of infection, and several residents, who later became secondarily infected, were gathered in the day room, it was postulated that the infectious aerosol was transmitted by this air current. CONCLUSIONS: The present results suggest that secondary infections can occur owing to aerosol advection driven by large-scale flow, even when the building design adheres to the ventilation guidelines established in Japan. Moreover, the CO2 tracer gas method facilitates the visualization of areas at a high risk of airborne infection and demonstrates the effectiveness of window opening, which contributes to improved facility operations and recurrence prevention.

2.
Sci Rep ; 12(1): 17642, 2022 Oct 21.
Article in English | MEDLINE | ID: covidwho-2087309

ABSTRACT

A coronavirus disease 2019 (COVID-19) cluster emerged in a manufacturing factory in early August 2021. In November 2021, we conducted a ventilation survey using the tracer gas method. Firstly, we reproduce the situation at the time of cluster emergence and examined whether the ventilation in the office was in a condition that increased the risk of aerosol transmission. Secondly, we verified the effectiveness of the factory's own countermeasure implemented immediately after the August cluster outbreak. Furthermore, we verified the effectiveness of several additional improvement measures on the factory's own countermeasures already installed in August. Under the conditions of the cluster emergence, the air changes per hour (ACH) value was 0.73 ACH on average. The ACH value was less than 2 ACH recommended by the Ministry of Health, Labour, and Welfare, suggesting an increased risk of aerosol transmission. The factory's own countermeasures taken immediately in August were found to be effective, as the ACH value increased to 3.41 ACH on average. Moreover, it was confirmed that additional improvement measures on the factory's own countermeasures increased the ACH value to 8.33 ACH on average. In order to prevent the re-emergence of COVID-19 clusters due to aerosol infection in the office, it was found that while continuing the factory's own countermeasure, additional improvement measures should also be added depending on the number of workers in the room. In a company, it is important that workers themselves continue to take infection control measures autonomously, and confirming the effectiveness of the measures will help maintain workers' motivation. We believe it is helpful that external researchers in multiple fields and internal personnel in charge of the health and safety department and occupational health work together to confirm the effectiveness of conducted measures, such as in this case.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , COVID-19/prevention & control , Japan/epidemiology , Respiratory Aerosols and Droplets , Ventilation , Manufacturing and Industrial Facilities
3.
Journal of Japan Air Cleaning Association ; 59(5):271-280, 2022.
Article in Japanese | Ichushi | ID: covidwho-1935194
4.
Environmental and Occupational Health Practice ; 2021.
Article in Japanese | J-Stage | ID: covidwho-1581665
5.
Environ Health Prev Med ; 26(1): 92, 2021 Sep 18.
Article in English | MEDLINE | ID: covidwho-1496136

ABSTRACT

BACKGROUND: Particulate matter (PM) is recognized as the most harmful air pollutant to the human health. The Yangon city indeed suffers much from PM-related air pollution. Recent research has interestingly been focused on the novel subject of changes in the air quality associated with the restrictive measures in place during the current coronavirus disease-2019 (COVID-19) pandemic. The first case of COVID-19 in Myanmar was diagnosed on March 23, 2020. In this article, we report on our attempt to evaluate any effects of the COVID-19-restrictive measures on the ambient PM pollution in Yangon. METHODS: We measured the PM concentrations every second for 1 week on four occasions at three study sites with different characteristics; the first occasion was before the start of the COVID-19 pandemic and the remaining three occasions were while the COVID-19-restrictive measures were in place, including Stay-At-Home and Work-From-Home orders. The Pocket PM2.5 Sensor [PRO] designed by the National Institute for Environmental Studies (NIES), Japan, in cooperation with Yaguchi Electric Co., Ltd., (Miyagi, Japan) was used for the measurement of the ambient PM2.5 and PM10 concentrations. RESULTS: The results showed that there was a significant reduction (P < 0.001) in both the PM2.5 and PM10 concentrations while the COVID-19-restrictive measures were in place as compared to the measured values prior to the pandemic. The city experienced a profound improvement in the PM-related air quality from the "unhealthy" category prior to the onset of the COVID-19 pandemic to the "good" category during the pandemic, when the restrictive measures were in place. The percent changes in the PM concentrations varied among the three study sites, with the highest percent reduction noted in a semi-commercial crowded area (84.8% for PM2.5; 88.6% for PM10) and the lowest percent reduction noted in a residential quiet area (15.6% for PM2.5; 12.0% for PM10); the percent reductions also varied among the different occasions during the COVID-19 pandemic that the measurements were made. CONCLUSIONS: We concluded that the restrictive measures which were in effect to combat the COVID-19 pandemic had a positive impact on the ambient PM concentrations. The changes in the PM concentrations are considered to be largely attributable to reduction in anthropogenic emissions as a result of the restrictive measures, although seasonal influences could also have contributed in part. Thus, frequent, once- or twice-weekly Stay-At-Home or Telework campaigns, may be feasible measures to reduce PM-related air pollution. When devising such an action plan, it would be essential to raise the awareness of public about the health risks associated with air pollution and create a social environment in which Telework can be carried out, in order to ensure active compliance by the citizens.


Subject(s)
Air Pollution/analysis , COVID-19/epidemiology , Particulate Matter/analysis , Humans , Myanmar/epidemiology , Pandemics , SARS-CoV-2
6.
Environmental and Occupational Health Practice ; : 2021-0010-OA, 2021.
Article in Japanese | J-STAGE | ID: covidwho-1477606
SELECTION OF CITATIONS
SEARCH DETAIL